Skip to content

Troubleshooting ​

Device Not Discovered ​

  • Ensure the device is powered on and connected to the same network as Homebridge.
  • Verify the Device ID and Local Key are correct.
  • Try adding the "ip" parameter to the device config to bypass auto-discovery.
  • Check that no other application (e.g. another Tuya plugin) is holding a connection — Tuya devices typically allow only one LAN connection at a time.

Devices on a Separate Subnet or VLAN ​

UDP discovery broadcasts do not cross routers, so a device on an IoT VLAN separated from Homebridge will never be discovered.

Configure both ip and version for those devices. The plugin then connects to them directly at startup and does not wait for, or run, discovery on their behalf:

json
{
  "type": "Outlet",
  "name": "Plug",
  "id": "xxxxxxxxxxxxxxxxxxxx",
  "key": "xxxxxxxxxxxxxxxx",
  "ip": "192.168.30.20",
  "version": "3.3"
}

TCP port 6668 must be reachable from Homebridge to the device.

Device Appears but Cannot Be Controlled ​

This usually means the DataPoint (DP) mapping is wrong for your device:

  • Check the Homebridge log for DP values being reported by the device.
  • Verify the type in your config matches your actual device.
  • Some devices require custom DP overrides via context parameters (e.g. dpPower, dpMode).

"Not connected" Errors ​

  • The device may have gone offline or changed IP.
  • Restart Homebridge to trigger re-discovery.
  • Set a static IP on the device via your router's DHCP settings and add "ip" to the config.

Repeated Reconnect Messages ​

A device that is unreachable is reported once, not once per retry:

[TuyaLocalPlatform] Device A2 Bulb 100w became unreachable; attempting to reconnect (ERR_PING_TIMED_OUT)
[TuyaLocalPlatform] Device A2 Bulb 100w is reachable again (1m 22s)

The individual socket errors behind an ongoing outage (ECONNRESET, EHOSTUNREACH, ERR_PING_TIMED_OUT, ERR_CONNECTION_TIMED_OUT) are still logged at debug level. Enable Homebridge debug mode (homebridge -D, or the debug toggle in the Homebridge UI) to see them.

Reconnection behaviour itself is unchanged: the plugin keeps retrying either way.

Local Key Changed ​

Local keys can rotate when:

  • A device is re-paired to the Tuya/Smart Life app.
  • Firmware is updated.
  • The device is factory reset.

Re-extract the local key using the method described in Getting Local Keys.

Protocol Version Mismatch ​

If a device does not respond, try setting the "version" parameter explicitly:

json
{
  "name": "My Device",
  "type": "Outlet",
  "id": "...",
  "key": "...",
  "version": "3.3"
}