Gates ​

A Gen2+ Shelly with one relay and two spare inputs can drive a gate, and the plugin will present it to OpenBridge and HomeKit as a gate rather than as a relay and two contact sensors.

json
{
  "ip": "192.168.1.201",
  "name": "Driveway",
  "gate": {
    "switch": 0,
    "openInput": 0,
    "closedInput": 1,
    "travelTime": 25
  }
}

That registers one device, Driveway - Gate, which opens, closes and reports where it is.

What the hardware actually offers ​

This is worth understanding before configuring anything, because it explains every quirk below.

A step-by-step gate operator has one control input. A pulse on it does not mean "open" or "close": it means next, and the board walks a fixed cycle.

text
closed ──pulse──▶ opening ──pulse──▶ stopped ──pulse──▶ closing ──pulse──▶ stopped ──pulse──▶ opening ...
                      │                                      │
                   (arrives)                              (arrives)
                      ▼                                      ▼
                    open                                   closed

So there is no command for "open". There is only "step", and what a step does depends entirely on what the board did last. HomeKit, meanwhile, asks for an absolute target: open or closed. Reconciling the two is the whole job of this feature.

Position comes from the operator's own limit switches, tapped as two Shelly inputs. One reads high when the gate is fully open, the other when it is fully closed. Neither high means the gate is somewhere in between, and that alone cannot tell you whether it is moving or standing still.

Wiring ​

SignalGoes toReads high when
Fully-open limitAn input (openInput, default 0)The gate is fully open
Fully-closed limitAn input (closedInput, default 1)The gate is fully closed
Step / start commandA relay (switch, default 0)Pulsed to step the board

Three things have to be true, and none of them can be discovered by the plugin:

  1. The relay is wired as a dry contact across the operator's step input. The Shelly is switching the board's own signal, not supplying voltage to it.
  2. The relay has an auto-off timer, around 500 ms, set in the Shelly app. The plugin sends one Switch.Set on=true and nothing else. See Why the auto-off matters.
  3. The two inputs are set to Switch mode and detached from the relays, so a limit switch closing does not also fire the step relay.

Both limit inputs must be inverted the same way ​

The two limit switches are one matched pair on a shared common, so the Shelly has to read them the same way round. invert is a per-input setting, and getting it wrong on one of them is silent: nothing complains, and the gate simply reports the opposite of the truth for half its travel.

The symptoms all point at the gate rather than at a checkbox in the app. A closed gate reads as mid-travel or open. Arriving at one limit looks like arriving at the other, so a gate that has just started opening is reported as closed, and the Home app re-sends the command, which steps the board again and stops the gate a foot into its travel. At full open both limits read high together, which this plugin reports as a wiring fault and HomeKit shows as an obstruction.

Normally-closed limit switches, the usual kind, need invert turned on. They conduct at rest and open at the limit, so "at the limit" is electrically low. Set both inputs the same.

The plugin compares the two at startup and says so when they disagree:

text
192.168.1.201: input:0 and input:1 disagree on "invert" (true vs false). Both limit
switches are the same kind, so both inputs need the same setting, or the gate will
report a position it is not in.

The plugin checks what it can at startup and logs what it finds:

text
192.168.1.201: gate "Driveway - Gate" on switch:0, open limit input:0, closed limit input:1

If the relay has no auto-off timer, or the inputs named do not exist on the device, it says so rather than running a gate on assumptions.

Why the auto-off matters ​

A pulse is one RPC call, Switch.Set on=true, and the device's own auto-off opens the relay again. The plugin deliberately does not send on=false itself.

The reason is what happens when the bridge dies at the wrong moment. If the plugin owned both halves of the pulse, a crash or a network drop between them would leave the relay closed, holding the operator's step input down indefinitely. On most boards that is a gate that stops answering its own remote, and the fix involves a ladder. Letting the device time its own pulse means nothing the bridge does can latch that contact.

Without an auto-off timer configured, the first command closes the relay and it stays closed. The plugin warns at startup:

text
192.168.1.201: switch:0 has no auto-off timer. The gate needs one (around 500 ms)
so each command is a clean pulse. Set it in the Shelly app.

Reaching a target ​

Because there is only "step", getting to a requested position can take more than one pulse. The plugin tracks where the board is in its cycle and sends as many as the cycle needs:

Gate isAsked forPulsesWhat happens
ClosedOpen1Starts opening
OpenClosed1Starts closing
OpenOpen0Already there
OpeningOpen0Already on its way
OpeningClosed2Stop, then reverse
Stopped mid-travel, was openingClosed1The board's next step already closes
Stopped mid-travel, was openingOpen3Close, stop, open

That last row is the hardware, not the plugin. A board parked mid-cycle always resumes in the opposite direction, so asking it to carry on the way it was going costs a full reversal. The gate visibly moves the wrong way for a moment. There is no way around it from software.

A gate does not leave its limit switch instantly ​

A limit switch releases when the gate has physically moved off it, a second or two after the motor starts. For that moment the gate is moving and the limits still report it parked, and believing that reading turns a running gate back into a stationary one.

This matters because the sequence above re-reads the position between pulses, so it can honour a change of mind. Without allowing for the delay the gate sets off, the next poll reports it still sitting on the limit it just left, the sequence decides it never started and pulses again, and on this hardware the second pulse means stop. The gate travels a foot and halts.

So a reading that puts the gate on the limit it was told to leave is ignored for departureSettle (default 4 seconds). Arrival at the limit it is travelling towards is believed at once, and once the window passes the reading is believed again, because a gate still on its limit by then genuinely never moved.

Raise it for a slow or heavy gate.

Pulses in a sequence are separated by pulseGap (default one second), because a board will ignore a second edge arriving too soon after the first. Sequences are capped at three pulses, so a gate that is not responding gets stopped rather than cycled back and forth forever.

Gates moved by something else ​

Most gate operations are not HomeKit ones: they are the remote, the keypad, or the button in the hall. The plugin never assumes it is the only thing driving the gate.

Direction is recovered from which limit the gate just left, which is always observable and needs no command to have been issued:

  • The closed limit releases → the gate is opening.
  • The open limit releases → the gate is closing.

So a gate opened by its remote shows as Opening in the Home app within a poll, then Open when it arrives, with the plugin having sent nothing.

Gates are polled once per second by default rather than the usual five, since position is a reading people watch change. Set pollInterval explicitly to override that.

Stopping mid-travel ​

HomeKit's garage door service has no stop: it can only ask for open or closed. The physical button is the only thing that halts a gate mid-travel, so the plugin exposes it as a step control on the OpenBridge device. That fires one raw pulse and lets the board do whatever comes next in its cycle, exactly as the wall button does.

Travel time ​

travelTime (default 30 seconds) is how long a full open or close may take before the gate is assumed to have stopped. It exists because the limit switches genuinely cannot distinguish a gate that is moving from one that was stopped halfway: both read "neither limit".

Set it a few seconds longer than your gate's slowest full travel. Too short and a slow gate briefly reports Stopped before arriving; too long and a gate halted by a remote keeps showing Opening until the timer runs out.

Powering the Shelly ​

Give the Shelly its own supply. Do not run it from the operator's accessory rail.

Those auxiliary outputs are sized for a pair of photocells, and a wifi device's transmit peaks are a different kind of load. Borrowing that rail has a specific failure mode, seen on a real installation, and it takes the gate out entirely:

  1. A pulse energises the relay coil, which is a current spike on the shared rail.
  2. The Shelly browns out mid-pulse, before its own auto-off has fired.
  3. The relay stays closed, holding the operator's step input down.
  4. The operator ignores its own remote, because the step input never releases.
  5. Nothing can command the relay back off, because the Shelly is wedged, and the stuck coil is part of what is holding the rail down.

It does not recover on its own. Only cutting power to the whole assembly releases the relay, and until someone does, neither the app nor the handset opens the gate.

A separate supply breaks the loop at step 2, which is the only step under your control. Everything else here is mitigation.

What the plugin does about it ​

A pulse is half a second and the device's own auto-off ends it, so the step relay should never be closed on two polls a second apart. When it is, that timer did not run and the relay is holding the step input down, which is the state where neither the app nor the handset opens the gate. The plugin says so and opens the relay itself.

This is worth attempting even though the sag that stops the timer often takes the device offline with it: the device may be left just responsive enough to answer, and clearing it from here saves someone walking out to cut the power. When the device has gone entirely, nothing can reach it, and cutting power is the only way out. That is the case the separate supply prevents, and why it remains the actual fix rather than this.

When the device cannot be reached ​

A gate does not stop being a gate while its controller is offline, but what happened during the gap is unknowable. So the first reading after an interruption is taken as the truth rather than as the next frame of a sequence: a gate that went away closed and came back open was opened by someone, and is reported as open, not as having been observed opening.

This matters more than it sounds. Direction is normally inferred from a limit having just been released, and "just" stops being true across an outage. A device that reboots and comes back with its inputs still settling would otherwise be read as a gate that started moving on its own, and a gate sitting closed would show as Opening in the Home app with nobody having touched it.

A gate whose Shelly is not answering is never pulsed. A request to an unresponsive device is not a no-op: it can arrive and be acted on while only the reply goes missing, which moves a heavy gate with nobody able to see that it did. Refusing the command is the safer half of that trade.

For the same reason, a pulse that fails leaves the position unknown rather than unchanged, and the next reading is adopted as the truth. And every pulse is logged, with what asked for it, because it is the one thing here that moves something physical and an incident cannot otherwise be told apart from someone using the remote.

A gate whose Shelly stops answering is reported to HomeKit by failing the reads, which the Home app shows as No Response. It is deliberately not reported with a StatusFault characteristic, the way this plugin's switch and meter accessories do.

StatusFault is not in the garage door service's required or optional set. hap-nodejs will attach it anyway with a warning, and iOS then validates the bridged accessory against the spec and drops it: the gate appears in the Home app once and is gone by the next refresh. A missing fault channel is a much smaller problem than a missing accessory.

Both limits high ​

Both limit inputs reading high at once is physically impossible: a gate cannot be fully open and fully closed. It means the sensing is broken, usually a shared common come loose.

The plugin holds the last known position rather than guessing, reports wiringFault: true in telemetry, and raises ObstructionDetected in HomeKit. HomeKit has no way to say "my sensors are lying", and an obstruction warning is the closest honest signal: it stops the position being trusted.

Options ​

OptionTypeDefaultDescription
namestringderivedReplaces the generated "<device> - Gate" name.
switchnumber0Relay index wired to the operator's step input.
openInputnumber0Input index reading high at the fully-open limit.
closedInputnumber1Input index reading high at the fully-closed limit. Must differ.
travelTimenumber30Seconds before a gate that has not reached a limit is assumed stopped.
pulseGapnumber1000Milliseconds between pulses in a multi-pulse sequence.
departureSettlenumber4000Milliseconds the gate may still press the limit it was told to leave.
invertInputsbooleanfalseTreat a low input as "at the limit", for inverted sensing.

The relay named in switch is not also exposed as a switch. A toggle that pulses the gate behind the gate accessory's back would leave the two disagreeing about where it is. Other relays on the same device are unaffected and still appear as switches.

Sliding gates, swing gates, garage doors ​

All the same to this plugin. It models "an operator with a step input and two limit switches", which is what most of them are.

HomeKit publishes it as a garage door opener, because that is the only HomeKit service that describes an opener with limit switches rather than a position percentage. The Home app will call it a garage door until you rename it; that is cosmetic and the behaviour is unchanged.